Below is a range of options available for the VLT AutomationDrive. If you require specialist advice on the information, Call or email Ray Hargreaves – CSE’s Danfoss Consultant on 023 8025 5757.
VLT® is a registered trademark. 1.2 Additional Resources Other resources are available to understand advanced frequency converter functions and programming. The VLT® AutomationDrive FC 301/FC 302 Programming Guide provides greater detail on working with parameters and shows many application examples. The VLT® AutomationDrive FC 301. 4.3 Danfoss VLT ® FlexConcept® 44 5 System Integration. 5.1.4 Manual Derating 45 5.1.4.1 Derating for Running at Low Speed 46. 10.1.1 Closed Loop Drive System 149. On the VLT AutomationDrive FC 302 and optional on the VLT AutomationVT Drive FC 322. This feature prevents the drive from starting unintentionally. Profisafe is available as an option. 7 Hot-pluggable LCP The Local Control Panel (LCP) can be plugged in or unplugged during operation. Settings are easily transferred via the.
MCA 101 Profibus
By operating the FC 300 frequency converter via a field bus you can reduce the capital cost of your system, communicate faster and more efficiently, and enjoy a simpler interface
- PROFIBUS DP V1 gives you wide compatibility, a high level of availability, supported by all major PLC vendors. Compatible with future versions
- Fast and efficient communication, transparent installation, advanced diagnosis and paremeterisation and auto configuration of process data via GSD-file
- A-cyclic parameterisation using PROFIBUS DP V1, PROFIdrive or Danfoss FC profile state machines, PROFIBUS DP V1, Master Class 1 and 2
MCA 104 DeviceNet
DeviceNet offers robust, efficient data handling because it is based on Producer / Consumer technology
- This modern communications model offers key capabilities that allow the user to effectively determine what information is needed and when
- Users also benefit from ODVA’s strong conformance testing policies, that ensure products are interoperable
MCB 101 General Purpose I/O Option
I/O option offers an extended number of control inputs and outputs
- 3 digital inputs 0 – 24 V : Logic ‘0’ < 5 V; Logic ‘1’ > 10V
- 2 analogue inputs 0 – 10 V : Resolution 10 bit plus sign
- 2 digital outputs NPN / PNP push pull
- 1 analogue output 0 / 4 – 20 mA
- Spring loaded connection
- Separate parameter settings
MCB 102 Encoder Option
A universal option for connection of encode feedback from either a motor or a process. Feedback for asynhronous or brushless servo (Permanent magnet) motors.
- Encode module supports Incremental encoders and SinCos encoders as Hyperface
- Power supply for encoders
- RS422 interface
- Plug and play principle
- Fit to all FC300 AutomationDrives
- Connection to all standard 5V incremental encoders
- Spring loaded connection
MCB 103 Resolver Option
Supports resolver feedback from brushless servo motors and feedback for flux vector controlled asynchronous motors in rough environments
- Primary voltage : 4-8 Vrms
- Primary Frequency : 2.5kHz – 15kHz
- Primary current max : 50 mA rms
- Secondary input voltage : 4 Vrms
- Resolution : 10 bit @ 4 Vrms input amplitude
- Spring loaded connection
- Separate parameter settings
MCB 105 Relay Options
Gives the possibility to extend the relay functions with 3 extra relay outputs. The relay option fits into slot B in FC 301 or FC 302 AutomationDrive.
Max Terminal Load:
- AC-1 Resistive load 240V AC – 2A
- AC-15 Inductive load @ cos Ф 0.4 – 0.2 A
- DC-1 Resistive load 240V AC – 1 A
- DC-13 Inductive Load @ cos Ф 0.4 – 0.1 A
Min. Terminal Load
- DC 5 V – 10 mA
- Max switch rate at rated load / min. load – 6 min-1 / 20 sec-1
- Plug and play principle and fits in to slot B
- Protected control cable connection
- Spring loaded connection of control wires
- Selection of relay functions in normal parameter settings
MCB 108 Safe PLC Interface
The FC 302 provides a safety input based on a single pole 24 V DC input.
For the majority of applications this input enables the user to implement afety in a cost effective way. For applications that work with mroe advanced products like Safety PLC, Lightcurtains etc, the new Safe PLC interface engables the connection of a two wire safety link.
The Safe PLC interface allows the Safe PLC to interrupt on the plus or the minus link without interfering the sensor signal of the Safe PLC.
MCO 305 Progammable Motion Controller
An integrated programmable Motion Controller for FC 301 and FC 302; it adds functionality and flexibility to the already very comprehensive standard functionality of these drives. MCO 305 is optimised for all types of positioning and synchronising applications. Basic Features include:
- Synchronisation (electronic shaft), Positioning and electronic Cam control
- 2 inputs supporting both incremental and absolute encoders
- 2 imputs supporting both incremental and absolute encoders
- 1 encoder output (virtual master function)
- 10 digital inputs 8 digital outputs
- Sending and receiving data via Filedbus interface (requires Fieldbus option)
- PC software tools for programming and commissioning
MCB 107 24VDC Supply Option
This option is used for connection to an external DC supply to keep the control section and any option installed active by mains power down. Slot D.
- Input voltage range – 24 V DC +/- 15% (max. 37 V in 10 sec)
- Max. input current – 2.2A
- Max. cable length – 75 m
- Input capitance load – < 10 uF
- Power-up delay – < 0.6 s
- Simple to install in drives on existing machines
- Keep the control board and options active by power cut
- Keep fieldbuses active by power cuts
- Available pre-installed in FC300 AutomationDrive from factory
LCP 102 Graphical Local Control Panel
Danfoss Vlt Fc 302 Manual
- Multi language display
- FC 300 status messages
- Quick menu for simple commissioning
- Parameter setting and explanation of parameter function
- Adjusting of parameters
- Full parameter backup and copy function
- Alarm logging
- Info bottom : explains the function of the selected item on display
- Hand operated start-stop or selection of Automatic mode
- Reset function
- Displaying trend graph
LCP 101 Numerical Local Control Panel
The numeric control panel offers an excellent MMI interface to FC 300 Automation. The LCPs supports both drive types FC 301 and FC 302.
- FC 300 status messages
- Quick menu for easy commissioning
- Parameter
- Parameter setting and adjusting
- Hand operated start-stop function or selection of Automatic mode
- Reset function
LCP Panel Mounting Kit
- IP65 Enclosure Front
- 3 m cable for connection of LCP and FC300
- Gasket for sealing
- Finger screws for easy fitting
- Supports LCP101 and LCP102
Profibus adaptor Sub D9 Connector
The adaptor makes linking of field bus connections pluggable.
Decoupling plate for fieldbus cables
Makes fieldbus mounting robus
IP21 / Type 12 (NEMA1) kit
The IP21 / Type 12 (NEMA1) kit is used for installation of FC 300 drives in dry environments. The enclosure kits are available for frame sizes A2 and A3.
- Supports FC 300 Automation drives power sizes 0.25 to 7.5kW
- Used on standard FC 300 AutomationDrives without and with mounted option modules
- IP41 on top side
- PG 16 and PG21 holes for glands
Danfoss Vlt Hvac Drive Fc 102 Manual
Removable Fan
The fan can easily be removed and remounted for easy cleaning
Power options available
Danfoss Vlt Automation Drive Manual
- Brake resistors
- LC filters
- dU / dt filter
- Harmonic filters (AHF)
Danfoss Vlt Automation Drive Manual Download Free Youtube